Indoor High Density PODs and Suites


Feature Summary
​
-
Fully scalable Indoor and outdoor PODs to support Edge applications, remote sites, and high-density suites, offering N or N+1 redundancy
​
-
Single SKU approach support pre-configuration and integration to exactly meet client requirements
​
-
Unrivalled POD intelligence, centralising the management and reporting of power, energy, PQ, plant equipment, cooling, environmental and security elements
-
Certified by the Uptime Institute to Tier 3
-
36 month fully managed and supported N-GEN Estate cloud service delivering business intelligence via date range driven reporting including Carbon reporting data
-
Highly efficient POD environment offering a PUE of between 1.05 and 1.09 at full load (from 10kW to 1MW and beyond)
​
-
Enhanced operational cost efficiencies
-
Full specification, design support, integration, commissioning, and deployment.



Scalable Mini MDC Solutions (single or double In-Row Cooling Units)
Simplified Business Intelligence
​
-
Centralised data collection via Management Gateway (requires a single IP address)
​
-
Real time monitoring, historical reporting and alerting/alarming via N-GEN Estate Management System (including 36 months fully supported Cloud based package)
​
-
Alerting and alarming for all monitored power, energy, environmental and cooling parameters against user defined thresholds (alerts via SNMP, SMS or email)
​​
-
Full audit log and role-based administration permissions
​
-
Date range driven reports include key power/energy parameters, environmental conditions, residual current monitoring and carbon (CO2 emissions)
​
-
Fully distributed power management system including continuous Residual Current Monitoring as an alternative to periodic inspection shutdowns (IEC 62020 refers)
​
-
High resilience, AI Ready, RPDU technology offering <1% accuracy
​
-
Compact and fully distributed​ overhead busway including a patented busway construction and tap-off design offering the highest levels of industry safety
​
-
Delivers improved economic efficiency, optimised maintenance and higher operational and system safety
​
-
Consilidated management across the entire EPMS
​
-
Effective Power Quality Management to BS EN 50160, global measuring accuracy Class 0.5 in accordance with IEC 61557-12 (2-120% nominal load), THD in accordance with IEC61000/1EEE 519: 2014




Outdoor Solutions
POD Builds
​
-
Existing site eg. Warehouse, Retail Unit, Landing Station, Base Station
​
-
Prefab or Prebuilt designs, POD and EDGE solutions
​
-
UI Certified Tier 3 designs for 100kW, 250kW, 500kW and 1MW PODs
​​
-
Resilient Infrastructure - HVAC/UPS/Generator Backup
​
-
AC 3 Phase and Single-Phase Power Distributions Panels
​
-
With-In-Row or Rear Door cooling modules 25kW to 100kW
​
-
External Chiller Plant with lower PUE configurations (Free Air Cooling)
​
-
100kW to Multi-Mega Watts
​
-
Scalability reduces CAPEX and OPEX on day 1
​
-
Incremental growth to meet changing business needs
​
-
Physical segregation for required areas eg. security entrance, plant room, reception, operations, etc
​
-
Secure, Energy Efficient, Robust, Resilient
​
-
Low PUE, High Efficiency, Any Tier
​
-
A clear cost saving company to alternative construction methods including brick-built construction
-
​
-
Incorporates all required infrastructure for a fully resilient, secure and high function ITE environment